Wagner Electronics Catalogue

Phone: 02-9798-9233 Fax: 02-9798-0017 Data & Computer 04-40 UPS CENTURION RT - POWERSHIELD DOUBLE-CONVERSION TYPE - SEPARATE BATTERY BANK REQUIRED As a True Online Double-conversion UPS, the UPS takes the AC signal, converts it to DC and then back to AC, thus eliminating any noise or electrical interference and delivering perfect 240Vac and 50Hz frequency to all equipment and will continue to feed in the case of a mains failure. Programmable sockets on the back so that the user may get extended backup on critical equipment. The optional “L” version is for “Long Run” has no internal batteries and instead has an increased power charger for up to 10 external Battery Banks. • True double-conversion • Output power factor 0.9 • User-friendly and easy-shift LCD display • Rack or Tower design • ECO and advanced ECO mode for energy saving • Output voltage regulation ± 1% • Generator compatible • Programmable power management outlets • Emergency Power Off function (EPO) • Hot swappable battery design • Available in 1000, 2000 and 3000 VA models • Ideal for medium density power protection • USB, RS232, SNMP and AS400 multiple comms’ ACCESSORIES Details Code Telescopic Rail Mounting Kit PSRAIL External SNMP Module PSCESNMPEE BATTERY BANKS Model Centurion RT Centurion RT Centurion RT Centurion RT Centurion RT Centurion RT Capacity 1000VA 2000VA 3000VA 1000VA 2000VA 3000VA Power 900W 1800W 2700W 900W 1800W 2700W Time * * * 15min/450W 17min/800W 16min/1200W Battery Nil Nil Nil 12V 9AH x3 12V 9AH x4 12V 9AH x6 Switch 4ms 4ms 4ms 4ms 4ms 4ms Size 480x438x88mm 600x438x88mm 600x438x88mm 480x438x88mm 600x438x88mm 600x438x88mm Weight 7Kg 8Kg 14Kg 10Kg 14Kg 28Kg Code PSCERT1000L PSCERT2000L PSCERT3000L PSCERT1000 PSCERT2000 PSCERT3000 Details Code 12x Battery Bank PSCERT2000 or PSCERT3000 PSRTBB12 6x Battery Bank PSCERT1000 PSRTBB6 The standard Centurion RT can extend to one or two external battery banks. The Long-Run (L) versions require at least one external battery bank and can charge up to ten in total for maximising load times. [L] Versions require at least one external battery bank. UPS CENTURION RACK - POWERSHIELD TRUE ONLINE DOUBLE CONVERSION. RACKMOUNT. NO BATTERIES BUT INCLUDES LARGE 4AMP INTERNAL CHARGER In applications where only limited three phase power is available yet a large single phase power supply is necessary, the PowerShield® Centurion 3/1 Rack ticks all the boxes. Recommended in applications where a balanced load is required, the Centurion 3/1 Rack Series has all of the feature of the Centurion range with the added ability of accepting three phase power to its input. Like the Centurion range, the 3/1 Rack range boasts the same User friendly LCD display that allows the operator to interrogate and program the UPS on the front panel as well as with the included software. The Centurion 3/1 Rack UPS will accommodate any standard 19 inch rack. • True double-conversion • True double-conversion • DSP technology guarantees high performance • Output powerfactor 0.8 • Wide input voltage range (110-300Vac) • Active power factor correction in all phases • Built-in phase auto adapt function simplifies wire installation • 50Hz/60Hz converter mode auto select • Eco mode operation for energy saving (ECO) • Emergency power off function (EPO) • Generator compatible • USB, RS-232 as standard • Intelligent slot for PSSNMP or PSModbus or PSAS400 • 3-stage extendable charging design for optimized battery performance • Adjustable battery numbers • Optional N+X parallel redundancy Model Centurion Rack Capacity 10K VA Power 8KW Battery External Weight 22Kg Code PSCER10KL3-1 Requires Battery Bank Description Code External SNMP Coms Card with EMD port PSSNMPEE Internal SNMP Coms Card with EMD port PSSNMPV4 Rack-Rails PSRK1100 PSCER6000/10K External Battery Bank. 20 x 12V 9AH PSCERBB20 MBS Wrap Around, Push Button interlock, 3 phase, 10kVA PS3MBSWPB10K MBS Change Over, Push Button interlock, 3 Phase, 10kVA PS3MBSCPB10K UPS CENTURION ACCESSORIES

RkJQdWJsaXNoZXIy NDQ2MDk=